BEIFENG GALLICO TECUMSEH COMPRESSORS & CONDENSATIO UNITS Serial SPECIFICATION
R22 MEDIUM/HIH BACK pressione
Compressor exempla | Nominal Power (HP.) | Refrigerant | Displacement (cm³) | Expansion fabrica | Aeris flow (m³/hr) | Evaporatio Temperature | Voltage | |||||
-25℃ | -15℃ | -10℃ | 0℃ | 7.2℃ | 15℃ | |||||||
AEZ 3340EH | 1/3 | R22 | 7.55 | C | 800 | 256 | 444 | 548 | 788 | 988 | 1221 | 208-220V/1/50HZ |
AEZ4440EHR | 1/3 | R22 | 7.55 | CN | 800 | 256 | 444 | 548 | 788 | 988 | 1221 | 208-220V/1/50HZ |
AEZ 9440TMHR | 1/3 | R22 | 7.55 | CN | 800 | 294 | 444 | 548 | 788 | 988 | 1221 | 220-240V/1/50HZ |
CAE 9460TMHR | 1/2 | R22 | 11.3 | CN | 800 | 410 | 653 | 808 | 1161 | 1426 | 1739 | 208-220V/1/50HZ |
CAJ 9480TMH/HR | 5/8 | R22 | 15.2 | CN | 1130 | 576 | 946 | 1155 | 1632 | 2036 | 2509 | 208-220V/1/50HZ |
TAJ 9480TMH/HR | 5/8 | R22 | 15.2 | CN | 1130 | 576 | 946 | 1155 | 1632 | 2036 | 2509 | 400V/3/50Hz |
CAJ 9510TMH/HR | 1 | R22 | 18.3 | CN | 980 | 711 | 1126 | 1374 | 1941 | 2411 | 2987 | 208-220V/1/50HZ |
TAJ 9510TMH/HR | 1 | R22 | 18.3 | CN | 980 | 711 | 1126 | 1374 | 1941 | 2411 | 2987 | 400V/3/50HZ |
CAJ9513TMH/HR | 1-1/8 | R22 | 24.2 | CN | 980 | 806 | 1348 | 1666 | 2370 | 2899 | 3523 | 208-220V/1/50HZ |
TAJ9513TMH/HR | 1-1/8 | R22 | 24.2 | CN | 980 | 806 | 1348 | 1666 | 2370 | 2899 | 3523 | 400V/3/50HZ |
CAJ 4517EHR | 1-1/4 | R22 | 25.95 | CN | 2200 | 1072 | 1692 | 2071 | 2978 | 3741 | 4681 | 208-220V/1/50HZ |
TAJ 4517TH/HR | 1-1/4 | R22 | 25.95 | CN | 2200 | 1072 | 1692 | 2071 | 2978 | 3741 | 4681 | 400V/3/50Hz |
CAJ 4519TH/HR | 1-3/4 | R22 | 34.45 | CN | 2250 | 1250 | 2144 | 2642 | 3767 | 4669 | 5739 | 208-220V/1/50HZ |
TAJ 4519TH/HR | 1-3/4 | R22 | 34.45 | CN | 2250 | 1250 | 2144 | 2642 | 3767 | 4669 | 5739 | 400V/3/50HZ |
FH 4522FH/HR | 2 | R22 | 40.8 | CN | 2250 | 1348 | 2257 | 2794 | 4028 | 5053 | 6297 | 208-220V/1/50HZ |
TfH 4522FH/HR | 2 | R22 | 40.8 | CN | 2250 | 1348 | 2257 | 2794 | 4028 | 5053 | 6297 | 400V/3/50HZ |
FH 4524FH/HR | 2 | R22 | 43.9 | CN | 2250 | 1282 | 2314 | 2910 | 4200 | 5322 | 6592 | 208-220V/1/50HZ |
TfH 4524FH/HR | 2 | R22 | 43.9 | ON | 2250 | 1282 | 2314 | 2910 | 4200 | 5322 | 6592 | 400V/3/50Hz |
FH 4531FH/HR | 2-3/4 | R22 | 58.1 | CN | 4800 | 1669 | 3611 | 4360 | 6163 | 7597 | 9277 | 208-220V/1/50HZ |
TfH 4531FH/HR | 2-3/4 | R22 | 58.1 | CN | 4800 | 1669 | 3611 | 4360 | 6163 | 7597 | 9277 | 400V/3/50HZ |
TfH 4540FH/HR | 3-1/2 | R22 | 74.25 | CN | 4600 | 1890 | 4157 | 5137 | 7438 | 9194 | 11300 | 400V/3/50Hz |
TAG 4546THR | 4 | R22 | 90.2 | CN | 7000 | 2347 | 4486 | 5569 | 8483 | 11244 | 14507 | 400V/3/50HZ |
TAG 4553THR | 4-1/2 | R22 | 10.7 | CN | 7000 | 3058 | 5360 | 6635 | 9745 | 12467 | 15797 | 400V/3/50HZ |
TAG 4561THR | 5 | R22 | 112.5 | CN | 6600 | 3218 | 5954 | 7607 | 11447 | 14317 | 17813 | 400V/3/50Hz |
TAG 4568THR | 6 | R22 | 124.4 | CN | 6000 | 3320 | 6579 | 8566 | 12759 | 16221 | 20116 | 400V/3/50HZ |
TAG 4573THR | 6-1/2 | R22 | 134.8 | CN | 6000 | 4613 | 7033 | 8739 | 12634 | 15589 | 19298 | 400V/3/50HZ |
TAGD 4590THR | 7-1/2 | R22 | 180.4 | CN | 11500 | 4700 | 8309 | 10574 | 15628 | 19486 | 23990 | 400V/3/50Hz |
TAGD4610THR | 9 | R22 | 201.7 | CN | 11500 | 5103 | 9354 | 12058 | 17926 | 22340 | 27393 | 400V/3/50HZ |
TAGD 4612THR | 10 | R22 | 225 | CN | 11000 | 6604 | 11749 | 14841 | 22107 | 27561 | 34072 | 400V/3/50HZ |
TAGD4614THR | 12 | R22 | 269.6 | CN | 10500 | 7104 | 12055 | 15443 | 23590 | 29775 | 37160 | 400V/3/50Hz |
Data euismod fundatur: 50Hz
Ambient Temp: 32℃
R134A MEDIUM MAGNUM RURSUM
Compressor exempla | Nominal Power (HP.) | Refrigerant | Displacement (cm³) | Expansion fabrica | Aeris flow (m³/hr) | Evaporatio Temperature | Voltage | |||||
-25℃ | -15℃ | -10℃ | 0℃ | 7.2℃ | 15℃ | |||||||
AEZ 4430YHR | 1/4 | R134A | 8.85 | CN | 410 | 162 | 311 | 393 | 604 | 778 | 982 | 208-220V/1/50HZ |
AEZ 3440YH | 1/3 | R134A | 12.05 | C | 800 | 228 | 410 | 519 | 768 | 969 | 1212 | 220-240V/1/50HZ |
CAE 4440YHR | 1/3 | R134A | 12.05 | CN | 800 | 228 | 410 | 519 | 768 | 969 | 1212 | 208-220V/1/50HZ |
AE 3440YH | 1/3 | R134A | 12.05 | C | 800 | 241 | 433 | 553 | 841 | 1081 | 1375 | 220-240V/1/50HZ |
CAE 4440YHHR | 1/3 | R134A | 12.05 | CN | 800 | 241 | 433 | 553 | 841 | 1081 | 1375 | 220-240V/1/50HZ |
CAE 4448YHR | 3/7 | R134A | 14.15 | CN | 800 | 248 | 486 | 627 | 937 | 1186 | 1482 | 208-220V/1/50HZ |
CAE 4456YHR | 7/16 | R134A | 16 | CN | 980 | 298 | 538 | 689 | 1034 | 1319 | 1669 | 208-220V/1/50HZ |
CAJ 4461YH/HR | 1/2 | R134A | 18.3 | CN | 980 | 339 | 620 | 782 | 1156 | 1475 | 1843 | 208-220V/1/50HZ |
TAJ 4461YH/HR | 1/2 | R134A | 18.3 | CN | 980 | 339 | 620 | 782 | 1156 | 1475 | 1843 | 400V/3/50HZ |
CAJ 4476YH/HR | 5/8 | R134A | 21.75 | CN | 1130 | 447 | 750 | 956 | 1446 | 1867 | 2393 | 220-240V/1/50HZ |
CAJ 4492YH/HR | 3/4 | R134A | 25.95 | CN | 980 | 494 | 925 | 1179 | 1742 | 2229 | 2776 | 208-220V/1/50HZ |
TAJ 4492YH/HR | 3/4 | R134A | 25.95 | CN | 980 | 494 | 925 | 1179 | 1742 | 2229 | 2776 | 400V/3/50HZ |
CAJ 4511YH/HR | 1 | R134A | 32.7 | CN | 980 | 803 | 1216 | 1478 | 2138 | 2687 | 3370 | 208-220V/1/50Hz |
TAJ 4511YH/HR | 1 | R134A | 32.7 | CN | 980 | 803 | 1216 | 1478 | 2138 | 2687 | 3370 | 208-220V/1/50HZ |
FH 4518YH/HR | 1-1/2 | R134A | 53.2 | CN | 2250 | 1163 | 1791 | 2250 | 3463 | 4488 | 5848 | 208-220V/1/50Hz |
TFH 4518YH/HR | 1-1/2 | R134A | 53.2 | CN | 2250 | 1163 | 1791 | 2250 | 3463 | 4488 | 5848 | 400V/3/50HZ |
FH 4525YH/HR | 2 | R134A | 74.25 | CN | 2250 | 1147 | 2128 | 2759 | 4154 | 5424 | 6945 | 208-220V/1/50HZ |
TFH 4525YH/HR | 2 | R134A | 74.25 | CN | 2250 | 1147 | 2128 | 2759 | 4154 | 5424 | 6945 | 400V/3/50HZ |
TAG 4528YH | 2-1/2 | R134A | 90.2 | CN | 3540 | 978 | 2302 | 3132 | 5062 | 6687 | 8697 | 400V/3/50HZ |
TAG 4534YHR | 3 | R134A | 100.7 | CN | 4800 | 1336 | 2818 | 3760 | 5977 | 7859 | 10184 | 400V/3/50HZ |
TAG 4537YHR | 3-1/4 | R134A | 112.5 | CN | 4500 | 1573 | 3258 | 4304 | 6698 | 8690 | 11133 | 400V/3/50HZ |
TAG 4543YHR | 3-1/2 | R134A | 124.4 | CN | 4500 | 1737 | 3493 | 4638 | 7314 | 9601 | 12443 | 400V/3/50HZ |
Data euismod fundatur: 50Hz
Ambient Temp: 32℃
R404A MEDIUM/REGRESSUS GRAVIS COMPRESSORSR
Compressor exempla | Nominal Power (HP.) | Refrigerant | Displacement (cm³) | Expansion fabrica | Aeris flow (m³/hr) | Evaporatio Temperature | Voltage | |||||
-25℃ | -15℃ | -10℃ | 0℃ | 7.2℃ | 15℃ | |||||||
AEZ 3440ZH | 1/3 | R404A | 7.55 | C | 800 |
| 448 | 552 | 783 | 970 | 1049 | 208-220V/1/50HZ |
AEZ 4440ZHR | 1/3 | R404A | 7.55 | CN | 800 |
| 448 | 552 | 783 | 970 | 1049 | 208-220V/1/50HZ |
AEZ 9440ZMHR | 1/3 | R404A | 7.55 | CN | 800 | 262 | 448 | 552 | 783 | 970 | 1049 | 220-240V/1/50HZ |
CAE 9460ZMHR | 1/2 | R404A | 11.3 | CN | 980 | 394 | 659 | 803 | 1117 | 1368 | 1472 | 208-220V/1/50HZ |
CAE 9470ZMHR | 9/16 | R404A | 13.3 | CN | 1130 | 520 | 847 | 1030 | 1441 | 1775 | 1915 | 208-220V/1/50HZ |
CAJ 9480ZMH/HR | 5/8 | R404A | 15.2 | CN | 1130 | 619 | 975 | 1176 | 1624 | 1992 | 2146 | 208-220V/1/50HZ |
TAJ 9480ZMH/HR | 5/8 | R404A | 15.2 | CN | 1130 | 619 | 975 | 1176 | 1624 | 1992 | 2146 | 400V/3/50HZ |
CAJ 9510ZMHR | 1 | R404A | 18.3 | CN | 980 | 773 | 1183 | 1427 | 1973 | 2398 | 2584 | 208-220V/1/50HZ |
TAJ 9510ZMHR | 1 | R404A | 18.3 | CN | 980 | 773 | 1183 | 1427 | 1973 | 2398 | 2584 | 400V/3/50HZ |
CAJ 9513ZMHR | 1-1/8 | R404A | 24.2 | CN | 980 | 861 | 1417 | 1718 | 2365 | 2869 | 3079 | 208-220V/1/50HZ |
TAJ 9513ZMHR | 1-1/8 | R404A | 24.2 | CN | 980 | 861 | 1417 | 1718 | 2365 | 2869 | 3079 | 400V/3/50HZ |
CAJ4517ZHR | 1-1/4 | R404A | 25.95 | CN | 2200 |
| 1757 | 2134 | 3029 | 3677 | 3960 | 208-220V/1/50HZ |
TAJ4517ZHR | 1-1/4 | R404A | 25.95 | CN | 2200 |
| 1757 | 2134 | 3029 | 3677 | 3960 | 400V/3/50HZ |
CAJ 4519ZHR | 1-3/4 | R404A | 34.45 | CN | 2250 |
| 2282 | 2731 | 3803 | 4643 | 5008 | 208-220V/1/50HZ |
TAJ 4519ZHR | 1-3/4 | R404A | 34.45 | CN | 2250 |
| 2282 | 2731 | 3803 | 4643 | 5008 | 400V/3/50HZ |
FH 4522ZHR | 2 | R404A | 40.8 | CN | 2250 |
| 2142 | 2664 | 3787 | 4676 | 5041 | 208-220V/1/50HZ |
TfH 4522ZHR | 2 | R404A | 40.8 | CN | 2250 |
| 2142 | 2664 | 3787 | 4676 | 5041 | 400V/3/50HZ |
FH 4524ZHR | 2 | R404A | 43.9 | CN | 2480 |
| 2397 | 2951 | 4160 | 5127 | 5529 | 208-220V/1/50HZ |
TFH 4524ZHR | 2 | R404A | 43.9 | CN | 2480 |
| 2397 | 2951 | 4160 | 5127 | 5529 | 400V/3/50HZ |
FH 4531ZHRE | 2-3/4 | R404A | 58.1 | CN | 4800 |
| 3416 | 4233 | 5990 | 7372 | 7939 | 208-220V/1/50HZ |
TFH 4531ZHR | 2-3/4 | R404A | 58.1 | CN | 4800 |
| 3416 | 4233 | 5990 | 7372 | 7939 | 400V/3/50HZ |
FH 4540ZHR | 3-1/2 | R404A | 74.25 | CN | 4800 |
| 4108 | 5016 | 7010 | 8609 | 9274 | 208-220V/1/50HZ |
TFH 4540ZHR | 3-1/2 | R404A | 74.25 | CN | 4800 |
| 4108 | 5016 | 7010 | 8609 | 9274 | 400V/3/50HZ |
FHD 4548ZHR | 4 | R404A | 87.8 | CN | 7000 |
| 4756 | 6237 | 9094 | 11059 | 11808 | 208-220V/1/50HZ |
TFHD 4548ZHR | 4 | R404A | 87.8 | CN | 7000 |
| 4756 | 6237 | 9094 | 11059 | 11808 | 400V/3/50HZ |
FHD 4562ZHR | 5 | R404A | 116.2 | CN | 6000 |
| 6673 | 8438 | 11749 | 13947 | 14767 | 208-220V/1/50HZ |
TFHD 4562ZHR | 5 | R404A | 116.2 | CN | 6000 |
| 6673 | 8438 | 11749 | 13947 | 14767 | 400V/3/50HZ |
TAG 4546ZHR | 4 | R404A | 90.2 | CN | 7000 |
| 4757 | 6013 | 8878 | 11256 | 12262 | 400V/3/50HZ |
TAG 4553ZHR | 4-1/2 | R404A | 100.7 | CN | 7000 |
| 5085 | 6357 | 9338 | 11769 | 12815 | 400V/3/50HZ |
TAG 4561ZHR | 5 | R404A | 112.5 | CN | 6600 |
| 5818 | 7351 | 10883 | 13766 | 14882 | 400V/3/50HZ |
TAG 4568ZHR | 6 | R404A | 124.4 | CN | 6000 |
| 6631 | 8506 | 12540 | 15550 | 16790 | 400V/3/50HZ |
TAG 4573ZHR | 6-1/2 | R404A | 134.8 | CN | 6000 |
| 7182 | 8881 | 12698 | 15853 | 17178 | 400V/3/50HZ |
TAGD 4590ZHR | 7-1/2 | R404A | 180.4 | CN | 11500 |
| 8968 | 11266 | 16265 | 20237 | 21877 | 400V/3/50HZ |
TAGD 461OZHR | 9 | R404A | 201.4 | CN | 11000 |
| 9796 | 12380 | 18172 | 22924 | 24918 | 400V/3/50HZ |
TAGD 4612ZHR | 10 | R404A | 225 | CN | 11000 |
| 12015 | 14846 | 20947 | 25768 | 27754 | 400V/3/50HZ |
TAGD 4614ZHR | 12 | R404A | 248.8 | CN | 10500 |
| 14074 | 17529 | 24416 | 29417 | 31386 | 400V/3/50HZ |
Data euismod fundatur: 50Hz
Ambient Temp: 32℃
Si quas quaestiones habes vel auxilium egeas, pete nos directe, auxilium online et operas in tempore tibi praebebimus.
Armorum refrigeration professionalem fabrica
Zhejiang Beifeng Refrigeratio ipsum Co., Ltd. Historia armorum refrigerationis fabricandi XXXV annos habet. Nunc, duas bases processus in Shengzhou, Zhejiang sitas habet, cum productione aedificationis 60.000 metrorum quadratorum. Tres societates venditionesque in Shanghai, Beijing, et Guangzhou constituit, cum valida vis technica, apparatu provectus, varietates perfectas et qualitatem stabilem. Societas inspectionem centri summus habet ut index refrigerationis productorum perficiendi detegat et invectum vacui generis belium effluo detectores pro condensariis et evaporatoribus habeat. Magnam vim habet in refrigeratione nationali industriae et magnum mercatum occupat, cum distributoribus in omnibus urbibus maioribus; Magna fama gaudet non solum in mercatu domestico, sed etiam in mercatu transmarino, et fructus exportantur in Europam, Asiam Meridionalem, Orientem Medium, Americam Septentrionalem, Africam, etc.
In processu refrigerationis, pulchrum consilium condenser est pars magna augendi vim efficiendi ratio refrigerandi ra...
In aerem industrialem condiciones refrigerationis systemata, evaporatores, condensatores, compressores et suffocare v...
Diversi condensatores secundum condensationem vaporis in genus superficiei (etiam genus partitionis appellatum...
Aer coolers adhiberi possunt ad refrigerandum vel condensationem, et late adhibentur in: expolitione, condensa...
Aestate, compressoris exhausti caloris relative altum est et manus eam attingere non potest. Secundum...