In processus refrigerationis, aequa ratio condensantis
In processu refrigerationis, pulchrum consilium condenser est pars magna augendi vim efficiendi ratio refrigerandi ra...
Nomenclature
1.Product Series: NPC Commercial Type: NPH-Industrial Type2.Fan Location:
30:300mm; 40:400mm; 50:500mm; 63:630mm; 80:800mm
3.Fan Quantitas
4.Internal Code
5. Fin Spacing . 04 est 4mm . VI est 6mm . 07 est 7mm . 10 est 9mm
Cubits technical
Capacitas in regula EN328 fundata est hoc modo:
Modus operating | SC1 | SC2 | SC3 | SC4 | SC5 |
Evap. siccus (Te) | 0 | -8 | -25 | -31 | -40 |
(Ta-Te) TD | 10K | 8K | 7K | 6K | 6K |
Evap. temperatus | 10 | 0 | -18 | -25 | -34 |
Superheat | 6.5 K | 5.2 K | 4.6 K | 3.9 K | 3.9 K |
RH | 85 % | 85 % | 95 % | 95 % | 95 % |
Parametri effectus ab ebm notam ventilationis motoris nituntur, et aer iactus ad solum propositum referendum est, ipse aer iactus a dispositione evaporatorum vel collocatione bonorum affectus est.
Product Features
1、High efficientiam movit fin exemplaris design
2、Special sine fluctu fin consilio in meliorem calorem transferre
3、ternam striatam aeris fistulam pro altioribus caloris exchanger efficientiam
4、 Imprimis motricium fan pro low temp, applicatione, volumen altum aeris & iactus aeris
5、 Optimized air fluxus pro unitatis frigidiore faciei area ut max attingat. facultatem
6、ptimized circa consilium ad refrigeretum plene evanescente
VII, importari notam e-calentium applicari e-defrost type
8、Casing cum albo membrana pro corrosione praesidium
9 Robust,state-of-in-es sheet metalli consilio et sscasing is available
10、 Securus movens consilium latus operimentum facile sustentationem
11、4-7mm fin Spacing ad libitum pro diversa applicatione
12、Dual fin spacing design is available for minimize gelu
XIII, Imprimis unitas frigidior Thracam est available pro speciali applicatione
14、 ual exhauriebat lance design evitanda aqua condensationis
15、 Hot gas defrost is available for gyros aliquorum exemplorum
XVI, Distributor subsidium vitare inopinatum tremor
17、Special "Floting tube" design pro magna unitate frigidior
18、 Aeris jet pro longiori iactu aëris praesto est ad quaedam exempla Robust, status-of-the-artis sheet metalli consilium et SS armamentarium is available
NPC Commercial Air-Cooler
Medium et High Temperature 300mm Fan Series
Fin Spacing 4mm
exempla | 301C04 | 301D04 | 302C04 | 302D04 | 302F04 | |
SC2 Cooling Capacity KW | Inlet Aeris 0℃ R404A | 2.0 | 2.5 | 4.0 | 5.0 | 5.8 |
Evaporatio -8℃ R22 | 2.0 | 2.4 | 4.0 | 4.9 | 5.7 | |
SC1 Cooling Capacity KW | Inlet Air 10℃ R404A | 2.7 | 3.4 | 5.5 | 6.9 | 8.2 |
Evaporatio -0℃ R22 | 2.7 | 3.4 | 5.5 | 6.9 | 8.2 | |
Aer flow m³/h | 1500 | 1450 | 3000 | 2900 | 2500 | |
Air lacta m | 7 | 6 | 8 | 7 | 6 | |
Net pondus kg | 18 | 20 | 32 | 35 | 38 | |
Fan Spec. | 1XØ300 | 1XØ300 | 2XØ300 | 2XØ300 | 2XØ300 | |
Fan Mot. Ampere A | 0.22 | 0.22 | 0.44 | 0.44 | 0.44 | |
Fan Mot.Power W | 68 | 68 | 136 | 136 | 136 | |
Electric Defrost A | 2.3 | 4.5 | 4.5 | 4.5 | 9.1 | |
Electric Defrost W | 1500 | 2500 | 3000 | 3000 | 5000 | |
AESTUARIUM OD inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | |
Exitus OD inch | 5/8 | 5/8 | 5/8 | 5/8 | 5/8 |
Medium et High Temperature 300mm Fan Series
Fin Spacing 4mm
exempla | 303D04 | 303F04 | 304F04 | |
SC2 Cooling Capacity KW | Inlet Aeris 0℃ R404A | 7.3 | 8.4 | 10.4 |
Evaporatio -8℃ R22 | 7.3 | 8.4 | 10.4 | |
SC1 Cooling Capacity KW | Inlet Air 10℃ R404A | 10.2 | 11.9 | 14.9 |
Evaporatio -0℃ R22 | 10.2 | 12.0 | 15.0 | |
Aer flow m³/h | 4350 | 3750 | 4720 | |
Air lacta m | 8 | 7 | 9 | |
Net pondus kg | 50 | 58 | 66 | |
Fan Spec. | 3XØ300 | 3XØ300 | 4XØ300 | |
Fan Mot. Ampere A | 0.66 | 0.66 | 0,88 | |
Fan Mot.Power W | 204 | 204 | 272 | |
Electric Defrost A | 5.5 | 10.9 | 13.6 | |
Electric Defrost W | 3600 | 6000 | 7500 | |
AESTUARIUM OD inch | 1/2 | 1/2 | 1/2 | |
Exitus OD inch | 5/8 | 5/8 | 7/8 |
*Praedictae perficiendi parametri in ebm notam ventilabrum motoris nituntur.
*meas shr comeceionwth metral lhe and ohaes ae comecion.
NPC Commercial Air-Cooler
Medium et Maximum Temperature 400mm Fan SeriesFin Spacing 4mm
exempla | 401C04 | 401D04 | 401F04 | 402C04 | 402D04 | 402F04 | |
SC2 Cooling Capacity KW | Inlet Aeris 0℃ R404A | 3.7 | 4.5 | 5.4 | 7.4 | 9.0 | 10.5 |
Evaporatio-8℃ R22 | 3.6 | 4.3 | 5.2 | 7.3 | 8.9 | 10.6 | |
SC1 Cooling Capacity KW | Inlet Air 10℃ R404A | 5.0 | 6.1 | 7.7 | 10.0 | 12.3 | 14.9 |
Evaporatio -0℃ R22 | 4.9 | 6.1 | 7.5 | 9.9 | 12.2 | 15.0 | |
Aer flow m³/h | 3000 | 2900 | 2550 | 6000 | 5800 | 5100 | |
Air lacta m | 12 | 11 | 10 | 13 | 12 | 11 | |
Net pondus kg | 31 | 32 | 35 | 47 | 50 | 57 | |
Fan Spec. | 1XØ400 | 1XØ400 | 1XØ400 | 2XØ400 | 2XØ400 | 2XØ400 | |
Fan Mot. Ampere A | 0.47 | 0.47 | 0.47 | 0.94 | 0.94 | 0.94 | |
Fan Mot.Power W | 135 | 135 | 135 | 270 | 270 | 270 | |
Electric Defrost A | 2.3 | 2.3 | 4.5 | 4.5 | 4.5 | 9.1 | |
Electric Defrost W | 1500 | 1500 | 2500 | 3000 | 3000 | 5000 | |
AESTUARIUM OD inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 5/8 | |
Exitus OD inch | 5/8 | 5/8 | 5/8 | 5/8 | 5/8 | 7/8 |
Medium et High Temperature 400mm Fan Series
Fin Spacing 4mm
exempla | 403D04 | 403E04 | 403F04 | 404E04 | 404F04 | |
SC2 Cooling Capacity KW | Inlet Aeris 0℃ R404A | 13.7 | 15.3 | 16.6 | 18.4 | 20.3 |
Evaporatio -8℃ R22 | 13.4 | 15.1 | 16.1 | 18.3 | 20.2 | |
SC1 Cooling Capacity KW | Inlet Air 10℃ R404A | 18.6 | 21.0 | 22.9 | 25.6 | 28.4 |
Evaporatio-0℃ R22 | 18.5 | 21.0 | 22.9 | 25.8 | 28.6 | |
Aer flow m³/h | 8700 | 8100 | 7650 | 10200 | 9800 | |
Air lacta m | 14 | 13 | 12 | 15 | 14 | |
Net pondus kg | 69 | 74 | 79 | 92 | 97 | |
Fan Spec. | 3XØ400 | 3XØ400 | 3XØ400 | 4XØ400 | 4XØ400 | |
Fan Mot. Ampere A | 1.41 | 1.41 | 1.41 | 1.88 | 1.88 | |
Fan Mot.Power W | 405 | 405 | 405 | 540 | 540 | |
Electric Defrost A | 6.8 | 13.6 | 13.6 | 16.4 | 16.4 | |
Electric Defrost W | 4500 | 7500 | 7500 | 9000 | 9000 | |
AESTUARIUM OD inch | 5/8 | 7/8 | 7/8 | 7/8 | 7/8 | |
Exitus OD inch | 7/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 |
*Praedictae perficiendi parametri in ebm notam ventilabrum motoris nituntur.
*meas shr comeceionwth metral lhe and ohaes ae comecion.
NPC Commercial Air-Cooler
Medium et Maximum Temperature 300mm Fan Series
Fin Spacing 6mm
exempla | 301C06 | 301D06 | 302C06 | 302D06 | 302F06 | 303F06 | 304F06 | |
SC2 Cooling Capacity KW | AESTUARIUM Air0℃ R404A | 1.7 | 2.1 | 3.4 | 4.3 | 5.3 | 7.8 | 9.6 |
Evaporatio -8℃ R22 | 1.7 | 2.0 | 3.4 | 4.1 | 5.1 | 7.5 | 9.6 | |
SC3 Cooling Capacity KW | Inlet Air-18℃ R404A | 1.1 | 1.4 | 2.4 | 2.9 | 3.7 | 5.3 | 6.5 |
Evaporatio-25℃ R22 | 1.1 | 1.4 | 2.3 | 2.9 | 3.7 | 5.2 | 6.4 | |
SC4 Cooling Capacity KW | Inlet Air -25℃ R404A | 0.8 | 1.1 | 1.7 | 2.3 | 2.8 | 4.0 | 5.0 |
Evaporatio -31℃ R22 | 0.8 | 1.1 | 1.8 | 2.3 | 2.7 | 4.1 | 5.0 | |
Aer flow m³/h | 1550 | 1500 | 3100 | 3000 | 2800 | 4170 | 5200 | |
Air lacta m | 8 | 7 | 9 | 8 | 7 | 8 | 10 | |
Net pondus kg | 17 | 19 | 31 | 34 | 36 | 55 | 65 | |
Fan Spec. | 1XØ300 | 1XØ300 | 2XØ300 | 2XØ300 | 2XØ300 | 3XØ300 | 4XØ300 | |
Fan Mot. Ampere A | 0.22 | 0.22 | 0.44 | 0.44 | 0.44 | 0.66 | 0.88 | |
Fan Mot.Power W | 68 | 68 | 136 | 136 | 136 | 204 | 272 | |
Electric Defrost A | 2.3 | 2.3 | 3.6 | 3.6 | 7.3 | 10.9 | 13.6 | |
Electric Defrost W | 1500 | 1500 | 2400 | 2400 | 4000 | 6000 | 7500 | |
AESTUARIUM OD inch | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | 1/2 | |
Exitus OD inch | 5/8 | 5/8 | 5/8 | 5/8 | 5/8 | 5/8 | 7/8 |
Medium et Maximum Temperature 400mm Fan Series
Fin Spacing 6mm
exempla | 401C06 | 401F06 | 402C06 | 402D06 | 402F06 | |
SC2 Cooling Capacity KW | AESTUARIUM Air0℃ R404A | 3.2 | 4.9 | 6.4 | 7.9 | 9.9 |
Evaporatio -8℃ R22 | 3.0 | 4.9 | 6.2 | 7.7 | 9.9 | |
SC3 Cooling Capacity KW | Aeris -18℃ R404A | 2.1 | 3.2 | 4.3 | 5.3 | 6.6 |
Evaporatio -25℃ R22 | 2.1 | 3.2 | 4.3 | 5.3 | 6.6 | |
SC4 Cooling Capacity KW | Inlet Air -25℃ R404A | 1.7 | 2.5 | 3.4 | 4.1 | 5.0 |
Evaporatio -31℃ R22 | 1.7 | 2.5 | 3.3 | 4.1 | 5.1 | |
Aer flow m³/h | 3200 | 2900 | 6400 | 6200 | 5800 | |
Air lacta m | 13 | 11 | 14 | 13 | 12 | |
Net pondus kg | 30 | 35 | 47 | 50 | 56 | |
Fan Spec. | 1XØ400 | 1XØ400 | 2XØ400 | 2XØ400 | 2XØ400 | |
Fan Mot. Ampere A | 0.47 | 0.47 | 0.94 | 0.94 | 0.94 | |
Fan Mot.Power W | 135 | 135 | 270 | 270 | 270 | |
Electric Defrost A | 2.3 | 4.5 | 4.5 | 4.5 | 9.1 | |
Electric Defrost W | 1500 | 2500 | 3000 | 3000 | 5000 | |
AESTUARIUM OD inch | 1/2 | 1/2 | 1/2 | 1/2 | 5/8 | |
Exitus OD inch | 5/8 | 5/8 | 5/8 | 5/8 | 7/8 |
*Praedictae perficiendi parametri in ebm notam ventilabrum motoris nituntur.
*meas shr comeceionwth metral lhe and ohaes ae comecion.
NPC Commercial Air-Cooler
Medium et Maximum Temperature 400mm Fan Series
Fin Spacing 6mm
exempla | 403D06 | 403E06 | 403F06 | 404F06 | |
SC2 Cooling Capacity KW | Inlet Aeris 0℃ R404A | 12.0 | 13.9 | 15.3 | 19.0 |
Evaporatio-8℃ R22 | 11.6 | 13.7 | 14.9 | 18.8 | |
SC3 Cooling Capacity KW | Aeris -18℃ R404A | 8.2 | 9.5 | 10.6 | 12.6 |
Evaporatio-25℃ R22 | 8.1 | 9.4 | 10.5 | 12.6 | |
SC4 Cooling Capacity KW | Inlet Air -25℃ R404A | 6.4 | 7.4 | 8.3 | 9.7 |
Evaporatio-31℃ R22 | 6.3 | 7.3 | 8.3 | 9.8 | |
Aer flow m³/h | 9300 | 9000 | 8700 | 11000 | |
Air lacta m | 15 | 14 | 13 | 15 | |
Net pondus kg | 69 | 74 | 79 | 100 | |
Fan Spec. | 3XØ400 | 3XØ400 | 3XØ400 | 4XØ400 | |
Fan Mot. Ampere A | 1.41 | 1.41 | 1.41 | 1.88 | |
Fan Mot.Power W | 405 | 405 | 405 | 540 | |
Electric Defrost A | 6.8 | 13.6 | 13.6 | 16.4 | |
Electric Defrost W | 4500 | 7500 | 7500 | 9000 | |
AESTUARIUM OD inch | 5/8 | 7/8 | 7/8 | 7/8 | |
Exitus OD inch | 7/8 | 1-1/8 | 1-1/8 | 1-1/8 |
*Praedictae perficiendi parametri in ebm notam ventilabrum motoris nituntur. Supra parametri perficiendi notam ventilationis motoris innituntur.
*meas shr comeceionwth metral lhe and ohaes ae comecion.Y meas shr comeceionwth metral lhe and ohaes ae comecion.
NPI Industrial Evaporator
Medium et Maximum Temperature Series
Fin Spacing 4mm
exempla | 502D04 | 502F04 | 502H04 | 503F04 | 503H04 | 504F04 | 504H04 | 632F04 | 632H04 | |
SC2 Cooling Capacity KW | Inlet Aeris 0℃ R404A | 20.0 | 25.3 | 28.3 | 36.7 | 41.3 | 55.1 | 49.5 | 46.96 | 52 |
Evaporatio -8℃ R22 | 20.0 | 25.3 | 28.5 | 37.0 | 41.8 | 54.1 | 54.1 | 47.11 | 52.31 | |
SC1 Cooling Capacity KW | Inlet Air 10℃ R404A | 27.4 | 35.1 | 40.0 | 51.6 | 58.9 | 77.2 | 77.2 | 66.15 | 73.79 |
Evaporatio -0℃ R22 | 27.7 | 35.6 | 40.7 | 52.5 | 60.1 | 68.7 | 78 | 66.74 | 74.87 | |
Aer flow m³/h | 14200 | 12800 | 11600 | 19200 | 17400 | 24400 | 20000 | 24500 | 22000 | |
Air lacta m | 22 | 21 | 20 | 22 | 21 | 23 | 22 | 27 | 24 | |
Net pondus kg | 158 | 178 | 198 | 254 | 285 | 320 | 355 | 243 | 288 | |
Fan Spec. | 2XØ500 | 2XØ500 | 2XØ500 | 3XØ500 | 3XØ500 | 4XØ500 | 4XØ500 | 4XØ630 | 4XØ630 | |
Fan Mot. Ampere A | 3.0 | 3.0 | 3.0 | 4.5 | 4.5 | 6.0 | 6.0 | 9.56 | 9.56 | |
Fan Mot.Power W | 1640 | 1640 | 1640 | 2460 | 2460 | 3280 | 3280 | 5260 | 5260 | |
Electric Defrost A | 13.6 | 13.6 | 13.6 | 22.6 | 22.6 | 28.4 | 28.4 | 17.3 | 20.2 | |
Electric Defrost W | 9000 | 9000 | 9000 | 12900 | 12900 | 16200 | 16200 | 11400 | 13300 | |
AESTUARIUM OD inch | 5/8 | 5/8 | 7/8 | 7/8 | 7/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | |
Exitus OD inch | 1-3/8 | 1-3/8 | 1-5/8 | 1-5/8 | 1-5/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 |
exempla | 633F04 | 633H04 | 634F04 | 634H04 | 635H04 | 802F04 | 802H04 | 803F04 | 803H04 | |
SC2 Cooling Capacity KW | AESTUARIUM Air0℃ R404A | 71.38 | 78.98 | 82.87 | 91.66 | 104.73 | 73.83 | 79.92 | 84.77 | 92.95 |
Evaporatio -8℃ R22 | 71.3 | 79.01 | 83.99 | 92.67 | 107.86 | 73.74 | 74.65 | 85.11 | 93.43 | |
SC1 Cooling Capacity KW | Inlet Air 10℃ R404A | 100.28 | 111.76 | 117.83 | 130.92 | 151.52 | 104.21 | 109.74 | 120.04 | 133.87 |
Evaporatio-0℃ R22 | 100.9 | 112.86 | 119.75 | 133.16 | 156.13 | 105.13 | 109.74 | 121.36 | 136.87 | |
Aer flow m³/h | 36500 | 33000 | 46000 | 40000 | 50000 | 32500 | 28000 | 40500 | 37000 | |
Air lacta m | 28 | 25 | 28 | 25 | 25 | 25 | 25 | 25 | 25 | |
Net pondus kg | 330 | 400 | 396 | 479 | 530 | 342 | 410 | 384 | 440 | |
Fan Spec. | 3XØ630 | 3XØ630 | 4XØ630 | 4XØ630 | 5XØ630 | 2XØ800 | 2XØ800 | 3XØ800 | 3XØ800 | |
Fan Mot. Ampere A | 14.3 | 14.3 | 19.1 | 19.1 | 23.8 | 7.8 | 7.8 | 11.7 | 11.7 | |
Fan Mot.Power W | 7890 | 7890 | 10520 | 10520 | 13150 | 3880 | 3880 | 5820 | 5820 | |
Electric Defrost A | 26 | 30.3 | 30.9 | 36.1 | 40 | 37.9 | 37.9 | 43.9 | 43.9 | |
Electric Defrost W | 17160 | 20020 | 2Ø400 | 23800 | 26400 | 25000 | 25000 | 29000 | 29000 | |
AESTUARIUM OD inch | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | |
Exitus OD inch | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 |
*Praedictae perficiendi parametri in ebm notam ventilabrum motoris nituntur.
*meas shr comeceionwth metral lhe and ohaes ae comecion.
NPI Industrial Evaporator
Medium et Maximum Temperature Series
Fin Spaceing 7mm
exempla | 502D07 | 502F07 | 502H07 | 503F07 | 503H07 | 504F07 | 504H07 | 632F07 | 632H07 | |
SC2 Cooling Capacity KW | Inlet Aeris 0℃ R404A | 17.0 | 22.0 | 25.1 | 32.2 | 36.9 | 42.9 | 48.7 | 40.3 | 47.1 |
Evaporatio -8℃ R22 | 17.0 | 22.0 | 23.4 | 32.4 | 37.1 | 42.5 | 46.0 | 40.3 | 47.1 | |
SC3 Cooling Capacity KW | Aeris -18℃ R404A | 11.0 | 14.5 | 17.0 | 21.0 | 24.3 | 29.0 | 33.7 | 26.2 | 31.1 |
Evaporatio -25℃ R22 | 11.3 | 14.8 | 17.2 | 21.5 | 24.9 | 29.2 | 33.8 | 26.6 | 31.5 | |
Aer flow m³/h | 15000 | 13600 | 12400 | 2Ø400 | 18600 | 26000 | 23800 | 27000 | 25000 | |
Air lacta m | 24 | 23 | 22 | 24 | 23 | 25 | 24 | 28 | 25 | |
Net pondus kg | 157 | 175 | 195 | 250 | 280 | 315 | 350 | 240 | 286 | |
Fan Spec. | 2XØ500 | 2XØ500 | 2XØ500 | 3XØ500 | 3XØ500 | 4XØ500 | 2XØ500 | 2XØ630 | 2XØ630 | |
Fan Mot. Ampere A | 3.0 | 3.0 | 3.0 | 4.5 | 4.5 | 6.0 | 6 | 9.56 | 9.56 | |
Fan Mot.Power W | 1640 | 1640 | 1640 | 2460 | 2460 | 3280 | 3280 | 5260 | 5260 | |
Electric Defrost A | 13.6 | 13.6 | 13.6 | 22.6 | 22.6 | 28.4 | 28.4 | 17.7 | 20.8 | |
Electric Defrost W | 9000 | 9000 | 9000 | 12900 | 12900 | 16200 | 16200 | 11700 | 13700 | |
AESTUARIUM OD inch | 5/8 | 5/8 | 7/8 | 7/8 | 7/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | |
Exitus OD inch | 1-3/8 | 1-3/8 | 1-5/8 | 1-5/8 | 1-5/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 |
exempla | 633F07 | 633H07 | 634F07 | 634H07 | 635H07 | 802F07 | 802H07 | 803F07 | 803H07 | |
SC2 Capacitas refrigeratio KW | Inlet Aeris 0℃ R404A | 61.5 | 71.4 | 72.3 | 83.7 | 98.7 | 60.72 | 67.12 | 72.18 | 81.37 |
Evaporatio -8℃ R22 | 61.1 | 71.1 | 72.8 | 84.2 | 96.5 | 54.85 | 58.92 | 71.95 | 75.62 | |
SC3Cooling Capacitas KW | Aeris -18℃ R404A | 40.1 | 47.6 | 45.8 | 54.2 | 60.1 | 41.3 | 47.2 | 47.58 | 54.67 |
Evaporatio-25℃ R22 | 40.6 | 47.9 | 46.6 | 55.2 | 61.97 | 41.39 | 48.09 | 48.34 | 55.35 | |
Aer flow m³/h | 40500 | 37500 | 51000 | 46000 | 57500 | 35500 | 32500 | 45000 | 40500 | |
Air lacta m | 28 | 26 | 28 | 26 | 25 | 25 | 25 | 25 | 25 | |
Net pondus kg | 325 | 393 | 389 | 470 | 530 | 342 | 410 | 384 | 440 | |
Fan Spec. | 3XØ630 | 3XØ630 | 3XØ630 | 3XØ630 | 3XØ630 | 3XØ800 | 3XØ800 | 3XØ800 | 3XØ800 | |
Fan Mot. Ampere A | 14.34 | 14.34 | 19.12 | 19.12 | 23.8 | 7.8 | 7.8 | 11.8 | 11.8 | |
Fan Mot.Power W | 7890 | 7890 | 10520 | 10520 | 13150 | 3880 | 3880 | 5820 | 5820 | |
Electric Defrost A | 26 | 30.3 | 30.9 | 36.1 | 44.5 | 37.9 | 37.9 | 43.9 | 43.9 | |
Electric Defrost W | 17160 | 20000 | 2Ø400 | 23800 | 29400 | 25000 | 25000 | 29000 | 29000 | |
AESTUARIUM OD inch | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | |
Exitus OD inch | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 |
*Praedictae perficiendi parametri in ebm notam ventilabrum motoris nituntur.
*meas shr comeceionwth metral lhe and ohaes ae comecion.
NPI Industrial Evaporator
Humilis Temperature Series
Fin Spacing:9mm
exempla | 502F10 | 503F10 | 503H10 | 504F10 | 504H10 | 632F10 | 632H10 | 633F10 | |
SC4 Cooling Capacity KW | Inlet Air -25℃ R404A | 10.2 | 14.8 | 17.8 | 20.5 | 24.3 | 18.3 | 22.5 | 28.1 |
Evaporatio -31℃ R22 | 10.4 | 15.1 | 18.1 | 20.6 | 24.5 | 18.6 | 22.9 | 28.4 | |
SC5 Cooling Capacity KW | Inlet Air-34℃ R404A | 8.2 | 11.5 | 13.9 | 16.8 | 20.6 | 17.7 | 21.7 | 23 |
Evaporatio -40℃ R22 | 8.6 | 12.3 | 14.9 | 17.5 | 21.2 | 17.6 | 21.5 | 23.4 | |
Aer flow m³/h | 13800 | 20700 | 18900 | 26800 | 24200 | 27600 | 25400 | 41400 | |
Air lacta m | 24 | 25 | 24 | 26 | 25 | 27 | 24 | 28 | |
Net pondus kg | 174 | 248 | 278 | 313 | 348 | 246 | 285 | 330 | |
Fan Spec. | 2XØ500 | 3XØ500 | 3XØ500 | 4XØ500 | 4XØ500 | 2XØ630 | 2XØ630 | 3XØ630 | |
Fan Mot. Ampere A | 3.0 | 4.5 | 4.5 | 6.0 | 6.0 | 9.56 | 9.56 | 14.3 | |
Fan Mot.Power W | 1640 | 2460 | 2460 | 3280 | 3280 | 5260 | 5260 | 7890 | |
Electric Defrost A | 13.6 | 22.6 | 22.6 | 28.4 | 42.6 | 17.3 | 20.2 | 26 | |
Electric Defrost W | 9000 | 12900 | 12900 | 16200 | 24300 | 11400 | 13300 | 17160 | |
AESTUARIUM OD inch | 5/8 | 7/8 | 7/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | |
Exitus OD inch | 1-3/8 | 1-5/8 | 1-5/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 |
exempla | 633H10 | 633F10 | 634H10 | 635F10 | 802F10 | 802H10 | 803F10 | 803H10 | |
SC4 Cooling Capacity KW | Inlet Air -25℃ R404A | 34.4 | 31.22 | 39.4 | 43.4 | 23.59 | 28.97 | 33.24 | 39.87 |
Evaporatio -31℃ R22 | 34.7 | 32.29 | 40 | 44.7 | 24.91 | 30.42 | 33.79 | 40.46 | |
SC5 Cooling Capacity KW | Inlet Air-34℃ R404A | 28.3 | 23.83 | 31.5 | 33.2 | 17.78 | 22.19 | 26.47 | 32.26 |
Evaporatio -40℃ R22 | 29 | 25.66 | 32.1 | 34.4 | 19.56 | 24.27 | 27.81 | 33.89 | |
Aer flow m³/h | 38100 | 52000 | 47200 | 59000 | 36000 | 33000 | 45600 | 41100 | |
Air lacta m | 25 | 28 | 25 | 25 | 25 | 25 | 25 | 25 | |
Net pondus kg | 400 | 396 | 479 | 530 | 342 | 410 | 384 | 440 | |
Fan Spec. | 3XØ630 | 4XØ630 | 4XØ630 | 5XØ630 | 2XØ800 | 2XØ800 | 3XØ800 | 3XØ800 | |
Fan Mot. Ampere A | 14.3 | 19.1 | 19.1 | 23.8 | 7.8 | 7.8 | 11.8 | 11.8 | |
Fan Mot.Power W | 7890 | 10520 | 10520 | 13150 | 3880 | 3880 | 5820 | 5820 | |
Electric Defrost A | 30.3 | 30.9 | 36.1 | 40 | 37.9 | 37.9 | 43.9 | 43.9 | |
Electric Defrost W | 20020 | 2Ø400 | 23800 | 26400 | 25000 | 25000 | 29000 | 29000 | |
AESTUARIUM OD inch | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | 1-1/8 | |
Exitus OD inch | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 | 2-1/8 |
*Praedictae perficiendi parametri in ebm notam ventilabrum motoris nituntur.
*meas shr comeceionwth metral lhe and ohaes ae comecion.
Evaporator Dimension
exempla | Dimensio (mm) | Exhaurire Location | ||||
L | H | W | C | E | ||
NPC301 | 730 | 450 | 500 | 390 | 477 | 32 |
NPC302 | 1180 | 450 | 500 | 390 | 930 | 32 |
NPC303 | 1600 | 450 | 500 | 390 | 1347 | 32 |
NPC304 | 1900 | 450 | 500 | 390 | 1647 | 32 |
NPC401 | 815 | 570 | 550 | 450 | 565 | 32 |
NPC402 | 1355 | 570 | 550 | 450 | 1105 | 32 |
NPC403 | 1895 | 570 | 550 | 450 | 1645 | 48 |
NPC404 | 2255 | 570 | 550 | 450 | 2005 | 48 |
exempla | Dimensio (mm) | Exhaurire Location | ||||
L | H | W | C | E | ||
NPI502 | 1990 | 850 | 700 | 590 | 1647 | 48 |
NPI503 | 2770 | 850 | 700 | 590 | 2427 | 48 |
NPI504 | 3375 | 850 | 700 | 590 | 3027 | 48 |
NPI632 | 2400 | 1000 | 720 | 590 | 2050 | 60 |
NPI633 | 3400 | 1000 | 720 | 590 | 3050 | 60 |
NPI634 | 4000 | 1000 | 720 | 590 | 3650 | 60 |
NPI635 | 4900 | 1000 | 720 | 590 | 4550 | 60 |
NPI802 | 3310 | 1235 | 850 | 690 | 2952 | 60 |
NPI803 | 3760 | 1235 | 850 | 690 | 3300 | 60 |
Evaporator Dimension
Zhejiang Beifeng Refrigeration Equipment Co., Ltd est celebre China NPI Industrial Type Air Cooler Factory and NPI Industrial Type Air Cooler Societas Et producti ad Europam South East Asia,Meridiem East,North AmericaAfrica etc. exportantur.
Si quas quaestiones habes vel auxilium egeas, pete nos directe, auxilium online et operas in tempore tibi praebebimus.
Armorum refrigeration professionalem fabrica
Zhejiang Beifeng Refrigeratio ipsum Co., Ltd. Historia armorum refrigerationis fabricandi XXXV annos habet. Nunc, duas bases processus in Shengzhou, Zhejiang sitas habet, cum productione aedificationis 60.000 metrorum quadratorum. Tres societates venditionesque in Shanghai, Beijing, et Guangzhou constituit, cum valida vis technica, apparatu provectus, varietates perfectas et qualitatem stabilem. Societas inspectionem centri summus habet ut index refrigerationis productorum perficiendi detegat et invectum vacui generis belium effluo detectores pro condensariis et evaporatoribus habeat. Magnam vim habet in refrigeratione nationali industriae et magnum mercatum occupat, cum distributoribus in omnibus urbibus maioribus; Magna fama gaudet non solum in mercatu domestico, sed etiam in mercatu transmarino, et fructus exportantur in Europam, Asiam Meridionalem, Orientem Medium, Americam Septentrionalem, Africam, etc.
In processu refrigerationis, pulchrum consilium condenser est pars magna augendi vim efficiendi ratio refrigerandi ra...
In aerem industrialem condiciones refrigerationis systemata, evaporatores, condensatores, compressores et suffocare v...
Diversi condensatores secundum condensationem vaporis in genus superficiei (etiam genus partitionis appellatum...
Aer coolers adhiberi possunt ad refrigerandum vel condensationem, et late adhibentur in: expolitione, condensa...
Aestate, compressoris exhausti caloris relative altum est et manus eam attingere non potest. Secundum...